How to choose topside seawater and firewater piping on an FPSO: duplex 2205, super duplex 2507 and copper-nickel 90/10 compared on PREN, chlorination, biofouling, strength and NORSOK practice.
On an FPSO, the seawater and firewater systems are among the largest small-to-medium bore networks on the topsides, and they are also the most corrosive. Choosing between duplex 2205, super duplex 2507 and copper-nickel 90/10 (UNS C70600) comes down to chlorination practice, flow velocity, crevice exposure and the weight budget for the topside module. This guide gives the decision basis engineers actually use.
| Material | UNS | PREN (typical) | Strength vs 316L | Key offshore standard |
|---|---|---|---|---|
| Duplex 2205 | S32205 | 34-36 | ~2x yield | ASTM A790 / A815 / A182 F60 |
| Super duplex 2507 | S32750 | 41-43 | ~3x yield | ASTM A790 / A815 / A182 F53 |
| Copper-nickel 90/10 | C70600 | n/a (Cu-Ni) | Lower | ASTM B466 / B171 |
PREN (%Cr + 3.3x%Mo + 16x%N) ranks resistance to chloride pitting. For continuously wetted or creviced seawater, offshore practice generally wants PREN at or above 40, which puts bare 2507 in the lead and leaves 2205 suitable only for ambient, free-flowing duty.
Firewater and cooling loops on an FPSO are routinely dosed with chlorine to control biofouling. Chlorination raises the oxidising potential of seawater and pushes the pitting and crevice temperatures down. A grade that survives clean ambient seawater can pit in chlorinated service. This is why 316L (PREN around 25) is not listed for seawater duty in NORSOK M-001, and why 2205 is used with care above about 25-30 °C in chlorinated loops.
Copper-nickel 90/10 takes a different route: it resists fouling by releasing a thin protective copper-oxide film, so it needs little or no chlorination. That is its advantage in quiescent firewater rings. Its limits are high velocity erosion-corrosion and sulphide pollution, and it is heavier than the duplex options for the same pressure rating.
Topside weight is a first-order cost driver. Super duplex 2507 yields at a minimum of 550 MPa, roughly three times 316L, so walls can be reduced substantially against the same design pressure. Specifying matching 2507 seamless pipe to ASTM A790 with A815 fittings keeps the chemistry consistent through the line. Welding needs a qualified WPS, controlled heat input, correct filler (commonly ER2594) and a ferrite check; poor procedure control is the usual reason a 2507 order fails.
Duplex 2205 is more forgiving to fabricate and is the value choice for ambient utility water, open drains and non-critical cooling. See 2205 seamless pipe for the base case.
In many ambient firewater systems yes, provided velocity and crevice conditions are controlled and the design accepts the change in fouling behaviour. Cu-Ni self-suppresses biofouling; duplex does not, so the water-treatment regime must be reviewed.
In warm or chlorinated seawater, usually yes: the higher PREN prevents the pitting that 2205 can suffer, and the higher strength cuts wall thickness and weight. In mild ambient utility water, 2205 is the better-value choice.
Ask for EN 10204 3.1 mill certificates with measured chemistry and calculated PREN, PMI, and third-party inspection (DNV, BV, SGS) if the project specification requires it. For duplex grades also confirm ferrite content and solution-annealed condition.
Tailan Metal supplies 2205, 2507 and Cu-Ni 90/10 pipe, fittings and flanges with mill certificates. Send your line list and service conditions for a quotation, or message us on WhatsApp.